3.8 Resetting to the factory default settings
To reset the network camera to the original factory settings, go to the Setup>System> Maintenance
web page (described in “3.5.5 System > Maintenance”) or use the Reset button on the network
camera, as described below.
Using the Reset Button
Follow the instructions below to reset the network camera to the factory default settings using
the Reset button.
1. Power off the network camera by disconnecting the power adapter.
2. Remove lower dome if not already done so.
3. Press and hold the Reset button with a straightened paperclip while reconnecting the power.
4. Keep the Reset button pressed for about 2 seconds.
5. Release the Reset button.
6. The network camera resets to factory defaults and restarts after completing the factory
reset.
The unit now obtains the IP address automatically via DHCP.
7. Reattach the dome.
CAUTION: When performing a Factory Reset, you will lose any settings you have saved.