Vista de página 209
RAIDWatch User’s Manual
Figure 11-11: System Information Window
Step 1. To access the window, click on the System Information icon
on the GUI navigation panel or select the command from the
Action command menu.
Step 2. Carefully check the display icons in front of the Device Name.
Devices are categorized by the data bus by which they are
connected. See the icon list below for more information:
Icon Description
RAID controller status
Status of I
2
C bus devices
Status of SAF-TE devices
Status of SES devices
Temperature sensors
Table 11-3: Device Icon
A Refresh button allows you to renew the information in cases when loop
IDs are changed or when an LIP has been issued.
NOTE:
Place your cursor on a specific item to display its device category.
System Information 11-12