Vicon SVFT-W23C Manual do Utilizador Página 6

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 11
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 5
Electrical motorized pan and tilt
with electronic control.
Units available in color and
day/night (NTSC/PAL) formats
and a variety of zoom and feature
capabilities.
18-32 VAC.
See Table 2.
Indoor:
Coax, Fiber, UTP: 0.8 A.
V
iconNet (TCP/IP): 1.2 A.
Outdoor:
Coax, Fiber, UTP: 1.4 A.
V
iconNet (TCP/IP): 1.8 A.
Indoor:
Coax, Fiber, UTP: 20 W.
V
iconNet (TCP/IP): 30 W.
Outdoor:
Coax, Fiber, UTP: 35 W.
V
iconNet (TCP/IP): 45 W.
Indoor:
Coax, Fiber, UTP: 1.14 btu/min
(0.29 kg-cal/min).
V
iconNet (TCP/IP): 1.7 btu/min
(0.43 kg-cal/min).
Outdoor:
Coax, Fiber, UTP: 2.0 btu/min
(0.5 kg-cal/min).
V
iconNet (TCP/IP): 2.6 btu/min
(0.64 kg-cal/min).
Note: These figures represent the
conversion of 100% of the
electrical energy to heat. Actual
percentage of heat generated will
be less and will vary from product
to product. These figures are
provided as an aid in determining
the extent of cooling required for
an installation.
V
ideo Out: See version type.
Power: 2-position removable
screw terminal block.
Control Input/Output: See version
type.
Relay Output: See version type.
A
larm Input: 8-position removable
screw terminal block.
75 ohms.
F1: 2AG, 1.6 A 250 VAC slo-blo.
F2: 2AG, 2.5 A 250 VAC slo-blo.
UL 2204.
FCC Class A.
360°.
-2.5° (-2.5° above horizon) to
92.5° (-2.5° past vertical).
V
ariable, 0.1 to 360°/sec
(120°/sec in 18X).
V
ariable, 0.1 to 42°/sec;
enable/disable.
V
ariable, 0.2 to 150°/sec
(90°/sec in 18X).
Drive Type:
Camera Types:
Input Voltage:
Maximum Operating
Distance:
Current (@24 VAC):
Power Consumption:
Heat Equivalent:
Standard Connecto
r
Types:
Video Output
Impedance:
Fuse:
Safety Standard:
Radio
Emission Rating:
Video Pan View:
Video Tilt View:
Pan Speed:
Autopan Speed:
Tilt Speed:
Less than 1.8 sec from end to
end.
16 max, programmable for size
and titling; capability to be
blanked out (22X and 23X only).
79 individual programmable
preset positions.
1 sec nominal.
0.23° maximum.
18X: 4 tours available.
22X/23X: 8 tours available.
32 programmable events per
tour. Events may be preset
positions with speed control,
alarm acknowledge, dwelltime
control, relay control, call
autotours, tour repeat or another
tour, save/recall camera status.
22X/23X: 2 autotours available
with 256 pan, tilt and zoom
functions per autotour.
Programming is done in real time
with joystick and push buttons.
A
utotours not available on 18X
model.
4 alarm inputs, individually
programmable.
Functional state enable/disable.
Report state (report on/off).
A
ctive state (high/low).
Mode (manual, momentary or
automatic) with programmable
dwell time control.
Set and reset action (preset
solve, relay on/off, tour, autotour.
A
larm titling.
1 relay output.
Power-on state definition (on/off).
Output type definition (momentary
or latching).
Relay function status titling.
Resistive Load: 0.3A @125 VAC;
1.5A @30 VDC.
Inductive Load: 0.15A @
125 VAC; 0.75A @ 30 VDC.
On-screen, menu-driven system
allowing full configuration of the
dome.
22X and 23X:16 individual,
programmable, zoom-scalable.
Zoom and Focus
Speed:
Sectoring:
Preset Capabilities:
Preset Solving
Speed:
Preset Accuracy
(Pan & Tilt):
Tour Capabilities:
Autotour Capabilities:
Alarm Capabilities:
Relay Output
Capabilities:
Control Display:
Privacy Masks:
ELECTRICAL
OPERATIONAL
Technical Information
Model No:
SurveyorVFT
Product Code: See
Table 1
SEC: 3 SPEC: V134 REV: 1203
6
Vista de página 5
1 2 3 4 5 6 7 8 9 10 11

Comentários a estes Manuais