174 Configuring the ViconNet System XX112-36-00 Rev 909 Kollector Hybrid Network Digital Video Recorder
NOTE: If the relevant drivers are not installed, the following message is displayed:
Click Close and install the relevant drivers.
4. When the drivers are correctly installed, click the Add Driver button to display a list of the pre-installed
drivers. The types include: PTZ joystick, relays, control panel, keypad, event and host protocol (PLC).
5. From the Driver Name list, select the required driver.
6. Select the Internal COM Address with which to communicate with the device, the Port Number and
the Baud Rate.
NOTES:
Ensure the Internal COM Address is different for each control driver, or the following message
appears:
.
For PTZ Joystick, the Baud Rate must be 4800.
7. Select/Deselect Auto start checkbox.
If selected, the control is automatically activated on system startup.
If not selected, the control must be activated manually in the Main screen, as described in the
section Activating a Control, below.
8. Click Save to save the settings.
9. Click Close to exit the Controls & Events Drivers Settings window.